REXSTEEL
Home / Aircraft shelter HAS · Shelter-type reference image
WONDER ARCH / HARDENED AIRCRAFT SHELTER

Aircraft Shelters (HAS·HAAS)

HAS · HAAS / WONDER ARCHAircraft Shelter Specialist Websitehasshelter.com · Open in a new window

From liners and SH DOOR blast doors to complete HAS·HAAS design.
REXSTEEL provides arch liners, blast doors, engineering and complete design through one point of contact.

Compare liners →
HAS · HAAS
Liners selected for the shelter design
610 × 355
Main corrugation dimensions (mm)
400 × 200
Deep-corrugation liner (mm)
E-COATING
Pretreatment · E-coating
DESIGN
Design · Supply · Site support
DOUBLE WAVE / SPALL LINER

Our civil-engineering flagship and
dedicated shelter liners are different.

B381 structural plate, double-wave Wonder Arch and 400×200 Steel Rolled Arch Liner are three distinct profiles. Increasing plate thickness alone does not satisfy a military spall-liner specification.

01 / CIVIL STRUCTURES · B381
Original REXSTEEL B381 single-corrugation 3D dimension illustration
Original REXSTEEL product dimension illustration

381 × 140 mm

Commonly called the 380×140 large corrugation. It has a main corrugation without Wonder Arch’s small reinforcing flutes.

REXSTEEL’s main civil structural plate product

REXSTEEL manufactures 381×140 as its main civil structural plate for culverts, wildlife crossings and similar structures. We do not use this product as a shelter spall liner.

Not a substitute for specified U.S. military / NATO spall liners
Not for aircraft shelters — REXSTEEL application policy

03 / STEEL ROLLED ARCH LINER
400×200 Steel Rolled Arch Liner cross-section
400×200 deep-corrugation liner · Cross-section

400 × 200 mm

Products subject to U.S. military / NATO project requirements

Subject to each project’s specifications and approvals

Steel Rolled Arch Liner
A single deep-corrugation liner without small reinforcing flutes.

5 mm-class steel · Check 6 GA requirements

Steel Rolled Arch Liner
Single deep corrugation · 5 mm-class plate
For 6 GA, confirm the contract’s base-metal thickness definition

Project-specific section, thickness and connection requirements apply
Detailed specifications available through technical consultation

Double corrugation is a key design feature with a major influence on limiting concrete spall.The main corrugation and reinforcing flutes affect local buckling and deformation. The complete system—section, thickness, connections, anchorage and concrete—must be assessed. Increasing B381 thickness alone does not make it a substitute for a specified liner.

PROJECT SPECIFICATION

Double corrugation · Minimum thickness

In the reviewed project specification, Section 05 30 00 — Steel Arch Liner §1.3 requires a double-fluted section and §2.1.1 a minimum 3.2 mm thickness. Changes to sections and connections are subject to approval.

TP 15 · §8.1

Approximately 610 mm primary pitch

The HAS development and testing history describes a 2-ft sinusoidal wave (609.6 mm). This passage alone does not specify a 355 mm depth, small reinforcing flutes, 3.2 mm thickness or REXSTEEL product certification.

SYSTEM DESIGN & APPROVAL

Whole-facility design · Approval

The design and review framework involving DESR 6055.09 and TP 26 referenced in TP 15 §1.5, UFC 3-340-01 and UFC 3-340-02, and product specifications are treated separately. Actual application follows the final contract specifications, drawings and approval conditions.

References: TP 15 Rev.5 (July 2026) and the reviewed project specification. Public UFGS 05 30 00 is titled Steel Decksand is a separate document. These descriptions are not universal U.S. military / NATO product certification or a quantified same-condition comparison. The ban on B381 for shelters is REXSTEEL’s application policy.

NUMERICAL ANALYSIS / WONDER ARCH

Blast Simulation Research Team

Structural responses to external blast and post-penetration detonation, studied with LS-DYNA by the Yeungnam and Kyungsung university team. Explore actual analysis images alongside key results.

Numerical analysis, not full-scale blast-test certification. These observations alone do not establish quantitative spall-velocity, depth or cone-angle compliance. They do not directly validate the new C-130 large-HAS concept or 4.5 mm extensions; those require separate analysis.

HISTORICAL FULL-SCALE TESTS

Records of full-scale blast testing

Historical U.S. Air Force and Defense Nuclear Agency tests provide context for shelter-system development. Distinguish the dates, structural types and reported outcomes.

1971 U.S. Air Force Concrete Sky detonation aerial photograph, AD0886769 Fig.10
Actual detonation · Aerial photographAD0886769 / AFWL-TR-71-65 · Fig.10 · Printed p.18 · 1971
Post-test wall-hinge deformation of neighbouring Shelter A, 1971, AD0886769 Fig.13
Deformation of a neighbouring shelter after testingSame report · Fig.13 · Printed p.21 · Hinge deformation, Shelter A wall
REPORT 01 / 1971

Concrete Sky, Phase IXB

Aircraft Shelter Explosives Quantity-Distance Evaluation
AD0886769 · AFWL-TR-71-65

Jon M. Jorgensen · U.S. Air Force Weapons Laboratory. Evaluated the effects of an internal explosion in a standard double-corrugated arch shelter on neighbouring shelters.

Scope of the findings The donor shelter was destroyed, and neighbouring shelters sustained varying damage. The photographs show the detonation and post-test condition.

REPORT 02 / Tests conducted in 1981

Third-generation HAS full-scale tests

High Explosive Testing of Hardened Aircraft Shelters
ADP001768 · DISTANT RUNNER

Ronald R. Bousek · U.S. Air Force / Defense Nuclear Agency. Full-scale external and internal blast tests of third-generation shelters evaluated explosives quantity-distance and structural response.

Scope of the findings Reports both external-blast protection and internal-blast failure behaviour. Some internal tests destroyed the shelter and aircraft; these are not presented as aircraft-dropped bomb tests.

Photographs extracted from the original report document historical test specimens. They do not constitute U.S. military certification of current REXSTEEL products or a guarantee for every blast condition. The 1971 report bears a 1977 public-release approval on its first page.

Related reporting / 25 April 2024 · RWNews (菱傳媒)

Debate over Taiwan shelter-liner specifications and thickness

The article attributes the following criticism to a source discussing Taiwan’s planned double-corrugated steel lining.

Traditional Chinese · Key excerpt

台灣規劃興建的「雙波浪鋼材襯裡」並非美軍規範材質,且厚度僅3mm

Translation

The double-corrugated steel lining planned for construction in Taiwan does not meet US military material specifications, and its thickness is only 3 mm.

Source: RWNews (菱傳媒) · 2024.04.25

MANUFACTURING

From fabrication to site assembly

Explore surface preparation, coating, quality checks and site assembly in photographs.

AIRCRAFT HANGAR / DESIGN OPTIONS

For the aircraft and protection objective,
three shelter concepts

Steel-framed hangars and concrete-covered HAS are distinct systems. Wonder Arch 610×355 liners are evaluated project by project in 3.2 / 4.0 / 4.5 mm thickness options.

01 / STEEL FRAME HANGAR

For large aircraft
Steel-framed hangar

The primary steel frame supports the large clear space. An inner liner, mineral wool, outer purlins and exterior armour plates are configured for the required protection.

50 m width · Planned door opening 44×14 m

A gallery space-planning example. Against C-130J overall dimensions, nominal door clearances are about 1.80 m per side and 2.16 m above. Door frames, equipment and operational margins require separate detailed review.

02 / CONCRETE-COVERED HAS

Standard-size
Concrete-covered HAS

Plan the Wonder Arch liner and concrete cover together. Check temporary support during pouring separately from the completed concrete structure.

Reference types: approx. 21.6 m and 25.0 m

Existing HAS widths in public TP 15 §8.1, not allowable maximum spans of our 4.5 mm product. HAAS sections and thicknesses also follow their own project specifications.

03 / LARGE HAS STUDY

C-130-class
Large-HAS study

A separate enlarged design, starting with the entrance and usable interior based on the C-130J’s 40.41 m wingspan and 11.84 m height.

Support and cover designed for the larger scale

A 22 m-class HAS cannot simply be scaled up with the same thickness and support count. Feasible 4.5 mm applications, concrete thickness, foundations and doors require whole-system structural and protection verification.

HAS provides aircraft protection; HAAS addresses protected alert readiness. The abbreviation alone does not determine the liner: mission, geometry, loads and approved specifications govern selection.

SUPPLY & COMPLETE DESIGN

One point of contact for design and supply

Agree the scope you need: liners and blast doors, structural and blast analysis, site support and complete design.

ASupply
  • Liner plates and accessories
  • Shop drawings · Assembly drawings · Quantities
  • Mill certificates
  • Export packing · Factory inspection
BSupply + Engineering
  • Everything in option A
  • Assembly manuals in English / local language
  • Construction-stage liner calculations endorsed by a Korean Professional Engineer
  • Temporary-support calculations and concepts · Installation plan
  • First-shelter site-start support + Remote support
CComplete design · Integrated engineering
  • Everything in option B
  • Engineer of Record support · Design review and verification
  • LS-DYNA liner simulation · Certification support
  • SH DOOR blast-door supply and design coordination
  • Complete HAS·HAAS design package — separate quotation

Complete design is quoted separately. REXSTEEL works with specialist design partners on HAS·HAAS design. Discipline scopes, EOR, professional endorsements and local approval / permitting responsibilities are defined in the project contract.

BLAST DOOR PARTNER

Blast doors, coordinated with the liner

SH DOOR TECH official website

With SH DOOR TECH, review openings, frames, rails, drives and the liner / concrete construction sequence together. Door type and protection requirements are set for each project.

REXSTEEL / CONTACT

Wonder Arch technical and supply enquiries

Tell us your facility geometry and required supply scope for product, design and site-support guidance. Detailed technical documents are provided under an NDA.

Email enquiry → Chat on WhatsApp ↗

Wonder Arch shelter concept

Ready to protect your air assets?

Email us for NDA-covered technical and supply-scope documents.

Request technical documents under NDA →

WONDER ARCH FILM

Wonder Arch promotional film

Promotional film including exhibition information.